Manage and review the status of the Base Unit firmware. The Base Unit firmware will also update the firmware of the Button(s) when (re)pairing. It is strongly advised to repair the Button(s) when the Base Unit has been updated! For more information, see “Pairing the Button(s)”
Image 6–65Example of the firmware updates
How to manage automatic updates
Depending on the local setup different methods of updating the firmware can be preferred. There are 3 methods available:
Automatic, Base Unit will be updated when a new firmware is released after being idle for more than 8 hours.
Notify, a notice when a new firmware is available will be visible, both on the firmware update page and the homepage.
Off, updating the Base Unit and keeping track of when a new firmware is released will be the responsibility of the system manager.
Select the desired method from the drop-down list after “Automatic Firmware updates”.
Manually up/downgrading firmware
Download the desired firmware from the Barco website.
Unzip the package and save the “.enc” update file in a location that is easily accessible.
Is the desired firmware lower than the currently installed firmware?
If no, continue with next step.
If yes, check the checkbox in front of “Allow firmware downgrade”.
Note: Only downgrade the firmware if absolutely necessary!
Click the push button with the text “Upload firmware...”.
The explorer will be opened to navigate to the “.enc” file location.
Wait for the update to be fully installed.
The Base Unit will be restarted once the update has been completed.
Repair the Button(s) to ensure that they have the correct firmware as well. For more information, see “Pairing the Button(s)”