9.7 Adjusting the distance meter

Warning: Laser Radiation - Do not stare into laser ranging beam, Class 2 IEC 60825-1: 2014, EN 60825-1:2014 +A11:2021.
Prerequisites

Make sure of the following:

Required tools

Torx screwdriver T10

Adjusting the distance meter
  1. Close the shutter.
  2. Activate the distance meter by pressing the push button.
  3. Check if the laser beam of the distance meter projects perpendicular to the screen, similar to the light source.

    • If yes, no further actions are needed.
    • If no, manipulate the three adjustment screws of the laser range finder (reference 1, Image 9–10) clockwise or counterclockwise in order to adjust the laser source. Use a T10 Torx screwdriver to adjust the adjustment screws.
    Image 9–10 Location of the adjustment screws.