4.1 Installation requirements

Warning: Ensure that the physical environment in which the unit is installed, complies at all times with the environmental requirements summarized in this chapter. Never use the unit in case not all requirements are fulfilled. Neglecting these will damage the unit and void the warranty.
Main power requirements
AC Power cord with NEMA 5/15 plug up to 13 A

The wires of the power cord are colored in accordance with the following code:

  • Green or yellow + green: Earth (Ground)
  • Blue or white: Neutral
  • Brown or black: Line (Live)
Power cord with GB 2099 plug up to 10 A

The wires of the power cord are colored in accordance with the following code:

  • Green + yellow: Earth (Ground)
  • Blue: Neutral
  • Brown: Line (Live)
AC Power cord (mains lead) with CEE 7 plug up to 10 A

The wires of the power cord are colored in accordance with the following code:

  • Green + yellow: Earth (Ground)
  • Blue: Neutral
  • Brown: Line (Live)
Environment conditions

Table below summarizes the physical environment in which the Encore3 may be safely operated or stored.

EnvironmentOperatingNon-Operating
Ambient Temperature0°C (32°F) to 40°C (104°F)-10°C (14°F) to 60°C (140°F)
Humidity5% to 85% RH Non-condensed0% to 95% RH Non-Condensed
Altitude-60 (-197Ft) to 3000m (9843Ft)-60 m (-197Ft) to 10000m (32810Ft)
Air cleanlinessClean office environment[5]N/A
Air clearance

Air outlets: minimum 60mm (2.36in)

Air inlets: minimum 60mm (2.36in)

N/A
Rack requirements

The Encore3 weighs 31-33 kg (68-72 lbs) when fully populated with Event Master cards and is 4 rack units tall. Distribute the devices in the rack evenly to avoid hazardous situations.

Ensure at least 1,27cm (1/2 inch) of clearance between Encore3 and other devices in the rack.


[5] Equivalent with cleanroom standard ISO 14644-1 ISO Class 9.